For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D3909 or ASTM D6380 Class M, shall be permitted. Slate shingles shall comply with ASTM C406. In areas where the average daily temperature in January is 25F (-4C) or less, Wood shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Spaced lumber decking CoL Refer to the manufacturer's technical bulletin regarding requirements for existing deck boards. Thermoplastic single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. or less. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Drip edges shall extend not less than. 12 oz/sq ft for preformed metal shingle systems. Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. The installation of sprayed polyurethane foam roofing shall comply with the provisions of this section. PDF Indiana Register FIRE PREVENTION AND BUILDING SAFETY COMMISSION CEB Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct water away from the vertical sidewall onto the roof or into the gutter. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. 12 oz/sq ft for preformed metal shingle systems. Modified bitumen roofing shall comply with the standards in Table 905.11.2. Where the roof, Where required, ice barriers shall comply with. Galvanized fasteners shall be used for steel roofs. 2018 International Residential Code (Irc) | Icc Digital Codes The installation of wood shakes shall comply with the provisions of this section. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. Spray-applied polyurethane foam insulation shall comply with ASTM C1029, Type III or IV or ASTM D7425. Wood shakes shall comply with the requirements of Table R905.8.5. Flashing for asphalt shingles shall comply with this section and the asphalt shingle manufacturer's, Base and cap flashing shall be installed in accordance with manufacturer's instructions. Flashing and counterflashing shall be made with sheet metal. R905.2.1 Sheathing requirements. The installation of mineral-surfaced roll roofing shall comply with this section. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Materials and methods of application used for recovering or replacing an existing, The structural roof components shall be capable of supporting the, Flashings shall be reconstructed in accordance with, Chapter 9 addresses the design and construction of, The 24 inch measurement shall be along the, Building-integrated photovoltaic products. References are to the 2018 International Residential Code (sections are designated as R). Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Where required, an ice barrier shall comply with Section 905.1.2. Stainless steel fasteners are acceptable for metal roofs. Interlayment shall comply with ASTM D226, Type I. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. 2018 International Residential Code (Irc) | Icc Digital Codes Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. Nominally, 2-by- Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. (R803.1) Spaced lumber sheathing is not allowed in Seismic Design Category D 2. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. PDF 2018 International Residential Code Changes Related to Wood Construction The installation of thermoset single-ply roofing shall comply with the provisions of this section. Chapter 9: Roof Assemblies, 2020 Indiana Residential Code | UpCodes Same as Maximum Ultimate Design Wind Speed, Apply in accordance with the manufacturer's, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B 370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet, ASTM B 209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum, Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, As an alternative, self-adhering polymer-modified bitumen, The standard calculations contained in ASTM D 7158 assume Exposure Category B or C and. Drip edges shall extend not less than. For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s. ASTM B209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum thickness for pressformed shingles. The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. R803.1 Lumber sheathing. Roof Sheathing Ring Shank nails have been added to Table R602.3(1) Fastening Schedule with the designation RSRS-01 (2-3/8" x 0.113") as an option for roof sheathing attachment. 2018 International Building Code (IBC) BASIC Upgrade to Premium CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES First Version: Aug 2017 All Codes I-Codes Legend Information Code Sections My Notes 2018 International Building Code (IBC) PREFACE arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right Asphalt shingles shall be tested in accordance with ASTM D7158. Interlayment shall comply with ASTM D226, Type I. %PDF-1.6 % Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. Asphalt shingles shall be used only on roof slopes of two units vertical in 12 units horizontal (2:12) or greater. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. conditions about your roof that may limit your product choices or affect the cost of your roofing job. 3. Modified bitumen membrane roofs shall have a design. 2018 IRC Simplified Wall Bracing Provisions 4 Objectives Upon completion, participants will be better able to: 1. R905.2.4.1 Wind Resistance of Asphalt Shingles, R905.14 Sprayed Polyurethane Foam Roofing, Section R907 Rooftop-Mounted Photovoltaic Systems, R907.1 Rooftop-Mounted Photovoltaic Systems, Section R909 Rooftop-Mounted Photovoltaic Panel Systems, Building-integrated photovoltaic products. Asphalt shingles shall be used only on roof. Asphalt shingles shall be fastened to solidly sheathed decks. The installation of thermoset single-ply roofing shall comply with the provisions of this section. Wood shakes shall comply with the requirements of Table R905.8.5. R902.2 Fire-Retardant-Treated Shingles and Shakes, R902.3 Building-Integrated Photovoltaic Product, R902.4 Rooftop-Mounted Photovoltaic Panels and Modules, R903.4.1 Secondary (Emergency Overflow) Drains or Scuppers, R904.3 Material Specifications and Physical Characteristics, Section R905 Requirements for Roof Coverings. Above-deck thermal insulation board shall comply with the standards in Table R906.2. R905.2.1 Sheathing requirements. R803.1 is for lumber sheathing. In areas where the average daily temperature in January is 25F (-4C) or less, Wood shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Section R803 Roof Sheathing R803.2 Wood Structural Panel Sheathing (Roof Online Note: This subsection covers plywood and OSB sheathing. Thermoplastic single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. See Table R503.2.1.1 for minimum allowable panel thickness by span and load.) For closed valleys (valley covered with shingles), valley lining of one ply of smooth roll roofing complying with ASTM D6380 and not less than 36 inches wide (914 mm) or valley lining as described in Item 1 or 2 shall be permitted. The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. Slate shingles shall be secured to the roof with two fasteners per slate. Each bundle of shakes shall be identified by a, The installation of built-up roofs shall comply with the provisions of this section and the manufacturer's. For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table R905.2.8.2. Wood shingles shall be laid with a side lap not less than 1, NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES, Roof flashing shall be not less than No. Interlayment shall comply with ASTM D226, Type I. Nails shall be corrosion resistant and not less than 11 gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. The installation of wood shakes shall comply with the provisions of this section. Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. or less, R905.2.4.1 Wind Resistance of Asphalt Shingles, R905.14 Sprayed Polyurethane Foam Roofing, R905.17 Building-Integrated Photovoltaic (BIPV) Roof Panels Applied Directly to the Roof Deck, Section R907 Rooftop-Mounted Photovoltaic Panel Systems, R907.1 Rooftop-Mounted Photovoltaic Panel Systems, Building-integrated photovoltaic products. The installation of asphalt shingles shall comply with the provisions of this section. Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. For closed valleys (valley covered with shingles), valley lining of one ply of smooth roll roofing complying with ASTM D 6380 and not less than 36 inches wide (914 mm) or valley lining as described in Item 1 or 2 shall be permitted. Galvanized fasteners shall be used for steel roofs. A base sheet that complies with the requirements of. Install 7/16 in.-structural sheathing (OSB or plywood) on the vertical face of the gable end wall. Base and cap flashing shall be installed in accordance with manufacturer's instructions. Where the existing roof or roof covering is water-soaked or has deteriorated to the point that the existing roof or roof covering is not adequate as a base for additional roofing. About this chapter: Chapter 10 contains requirements for the construction, seismic reinforcing and anchorage of masonry chimneys and fireplaces; and establishes standards for the use and installation of factory-built chimneys, fireplaces and masonry heaters. PDF 2018 IRC UPDATE Handout 9-1-18 - ICC Asphalt shingles shall be fastened to solidly sheathed decks. Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, ASTM D6162; D6163; D6164; D6222; D6223; D6298, As an alternative, self-adhering polymer-modified bitumen, As an alternative, a minimum 4-inch-wide (102 mm) strip of self-adhering polymer-modified bitumen membrane complying with ASTM D1970, installed in accordance with the, The cap nail shank shall be not less than 0.083 inch (2.11 mm) for ring shank cap nails and 0.091 inch (2.31 mm) for smooth shank cap nails. Install flashing at roof penetrations and wall intersections. 2018 IRC Residential Building Guides for Homeowners Re-Roof - Coweta Sections of flashing shall have an end lap of not less than 4 inches (102 mm). 2018 International Residential Code (Irc) | Icc Digital Codes The installation of wood shakes shall comply with the provisions of this section. SECTION R801 GENERAL. Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). PDF Guidelines for asphalt shingle roofing - Minnesota Allowable spans for lumber sheathing shall conform to IRC Table R803.1. Slate shingles shall be secured to the roof with two fasteners per slate. R905.2.2 Slope. The installation of slate shingles shall comply with the provisions of this section. Base flashing shall be of either corrosion-resistant metal of minimum nominal 0.019-inch (0.5 mm) thickness or mineral-surfaced roll roofing weighing not less than 77 pounds per 100 square feet (4 kg/m. Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. Reroofing shall not be required to meet the minimum design, For roofs that provide positive drainage, recovering or replacing an existing, Complete and separate roofing systems, such as standing-seam metal roof systems, that are designed to transmit the roof loads directly to the building's structural system and do not rely on existing roofs and, Where the existing roof has two or more applications of any type of. Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, ASTM D6162; D6163; D6164; D6222; D6223; D6298, As an alternative, self-adhering polymer-modified bitumen, As an alternative, a minimum 4-inch-wide (102 mm) strip of self-adhering polymer-modified bitumen membrane complying with ASTM D1970, installed in accordance with the, The cap nail shank shall be not less than 0.083 inch (2.11 mm) for ring shank cap nails and 0.091 inch (2.31 mm) for smooth shank cap nails. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs. The International Residential Code (IRC) and the Residential Edition of the Florida Building Code (FBC) both refer to Table R503.2.1.1(1) of the APA Engineered Wood Construction Guide for specs. 2021 International Residential Code (Irc) | Icc Digital Codes Modified bitumen roofing shall comply with the standards in Table R905.11.2. Interlayment shall comply with ASTM D226, Type I. Slate shingles shall comply with ASTM C406. For closed valleys (valley covered with shingles), valley lining of one ply of smooth roll roofing complying with ASTM D6380 and not less than 36 inches wide (914 mm) or valley lining as described in Item 1 or 2 shall be permitted. Liquid-applied roofing shall comply with ASTM C836, C957, D1227, D3468, D6083, D6694 or D6947. hbbd```b``3@$R&5d}"uA$$X ,>,rLYfH 2o2dbO C"=Vbz CHEX/#300 k Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. Each bundle of shakes shall be identified by a, The installation of built-up roofs shall comply with the provisions of this section and the manufacturer's. Self-adhering polymer-modified bitumen. For roofs that provide positive drainage, re-covering or replacing an existing, Complete and separate roofing systems, such as standing-seam metal roof systems, that are designed to transmit the roof loads directly to the building's structural system and do not rely on existing roofs and, The application of a new protective coating over an existing spray polyurethane foam roofing system shall be permitted without tear-off of existing, Where the existing roof has two or more applications of any type of.